On demand · Product video
Create a first article inspection report in Quality Inspector
For manufacturers that need a first article inspection report (Form 3) built from ballooned drawings and recorded test results.

Summary
Quality Inspector can print a first article inspection report (Form 3) from a quality inspection test. The video sets a template's type to balloon or bubble, which adds fields for the balloon number and characteristic designator, and explains that the balloon number must be filled in to use the report. It then walks through where each section of the report comes from: template instructions for the reference location, recorded tools for design tooling, related tests for non-conformance numbers, test notes for comments, and Quality Inspector setup for the prepared by contact. The part number, part name, lot or serial number, and report number come from the source item and the test.
Key topics
- Set a template type to balloon or bubble
- Add balloon numbers and characteristic designators
- Fill report sections from instructions, tools, and notes
- Run the first article inspection report from a test
Read the transcript
Quality Inspector has introduced a first article inspection report. To have your template use the first article inspection report, we’re first going to navigate to the template, and in the template type we’re going to choose the new option for balloon or bubble. First article inspection reports require either balloon drawings or bubble drawings to go with them, and you would typically have that as a template attachment or a record link of some nature.
When the template type is balloon or bubble, new fields show up: the balloon number, or characteristic number, and the characteristic designator. These can be used to reference the specific balloon drawing callouts, as well as the characteristic designator for that specific callout. Depending on how you’ve configured your fields, some of your fields might even be named the same, and your descriptions might already have the balloon number in them. The balloon number does need to be filled in to use the FAIR Form 3, the first article inspection report Form 3.
Once your template is configured as balloon or bubble and you’ve filled in the characteristic designators and the balloon numbers, your quality inspection tests will have the option in the report section for this first article inspection report. If your report is not configured to have balloon numbers or balloon drawings, the first article inspection report is not going to be available as an option.
The first article inspection report follows the standard convention. The characteristic number here represents the balloon number, or bubble number, from the quality inspection template. The reference location comes from the first instruction that’s configured. If we navigate back to our template temporarily and go to our instructions, we’re going to see that first instruction configured on the system. Likewise, for brakes, we have the first comment, and these represent the instruction that’s going to show in the first article inspection report.
For example, there are no work instructions yet here, so we could reference drawing location F3, top left quadrant. We’ll say part three, upper left. Okay, so let’s head back to our existing test and run that first article inspection Form 3, and we can see where that reference location is being used for that standard section six of the first article inspection Form 3.
The characteristic designator comes from the template itself. We had major, minor, nothing, and then critical, and these come from the template. The result section is split into the measured value, so in the case of numbers you’ll see the actual numeric values, and it also puts in the resulting grade. In this case there’s a pass or fail grade, and I’ve got one value still in progress.
For the design qualification and tooling section, this uses the tools that have been recorded and designated on the template itself. As an example, for the gear shift check, we can see in the tools that I’ve got the caliper with an identification number of 001, and I’ve also got a generic gauge just called height gauge. If we take a look at the template and how it’s configured, we simply have the caliper configured to be used and the height gauge configured to be used, and we’ll notice how the description is used on the report.
All right, so in this scenario I’ve got two tools. For a first article inspection report Form 3, it’s more typical that there would be one tool used. However, if you do have multiple tools, they’re separated by a comma in this section, just like we see here. If you have tool identification numbers recorded, they show up in parentheses. Alternatively, if you know ahead of time the specific serial numbers or very specific tools to use, you can configure them in the Quality Inspector available tools and then configure that on the template.
In my scenario, I’ve just got a generic caliper configured, and when I’m recording the results, that’s when I record the specific tool identification number I’m using. In this example down here, I don’t have a tool identification number, so it’s simply showing the description of the gauge itself.
The non-conformance number refers to any test that you’ve created from that specific test line, where the test and the test line match. So if we created another quality inspection test and configured it in our source configuration to match, we would see the non-conformance number here. If you’re recording non-conformance numbers from another system, you would probably need to customize the report to track that field or look up the value of your other non-conformance number.
Section 14, comments and additional details, comes from the notes recorded on the quality inspection test itself. We can see here that we’ve got “gear shift seems high,” and if we go back and look at the report, we see “gear shift seems high” in the notes section as well. If we add some more details here, such as “it should be lower,” we’ll see that reflected in the report.
The prepared by section is filled in only if you’re using the COA contact number on the Quality Inspector setup. If we navigate to our Quality Inspector setup, right now it’s blank, but if we choose a person, let’s choose Greg Chapman, and rerun the report, it’ll have the person’s name and the other details you’ve configured for that person.
The part number is simply the source item number that is mapped from your test, and the part name is the description from the item card for that part number. In the serial number section, if you’re using serial numbers for your quality inspection tests, it lists the serial number. If you’re using lot numbers instead, it lists the lot number, and if you’re using both, it lists both. So you should be able to use this report whether the item is serial tracked, lot tracked, or both.
The report number is just the quality inspection test number itself. For example, this quality inspection test is number 28, and we see 28 on the report.
Questions about this webcast?
Send your question and the Insight Works team will reply by email. Ready to plan a project? Contact your Microsoft Partner.