      A Unit of Measure was not found for Prod. Order Routing Line Status Firm Planned, Order No. FPN-000001, Operation No. 010. Please navigate to Work Center MC-01 Machine Shop Workstation 01 and ensure the unit of measure is setup. After that please navigate to the the routing line and make sure that a unit of measure is set up, this can often be done by refreshing the production order after correcting the missing information.

      Internal session ID:
      153c332b-5bd0-4e0f-a050-c04e3d9af8fe

      Application Insights session ID:
      7b82a405-e7a1-4c6a-ac96-dada19d5240c

      Client activity id:
      c14ebadc-abb4-4c23-aea4-6af60fc0b957

      Time stamp on error:
      2024-05-07T08:22:54.8480798Z

      User telemetry id:
      16a3e192-ac77-440b-a723-fb5f280dccc5

      AL call stack:
      “IWX Mx Segment Factory”(CodeUnit 70098291).getSegmentRate line 45 – MxAPS Advanced Finite Capacity Scheduling by Insight Works
      “IWX Mx Segment Factory”(CodeUnit 70098291).FillSingleFromProdOrdRtngLine line 33 – MxAPS Advanced Finite Capacity Scheduling by Insight Works
      “IWX Mx Segment Factory”(CodeUnit 70098291).FillFromOperation line 21 – MxAPS Advanced Finite Capacity Scheduling by Insight Works
      “IWX Mx Buffer Factory”(CodeUnit 70098294).FillOperationBuffersFromRoutingLine line 75 – MxAPS Advanced Finite Capacity Scheduling by Insight Works
      “IWX Mx Buffer Factory”(CodeUnit 70098294).FillProdOrderBuffers line 25 – MxAPS Advanced Finite Capacity Scheduling by Insight Works
      “IWX Mx Buffer Factory”(CodeUnit 70098294).Populate line 29 – MxAPS Advanced Finite Capacity Scheduling by Insight Works
      “IWX Mx Engine Request”(XmlPort 70098270).CreateBuffers line 5 – MxAPS Advanced Finite Capacity Scheduling by Insight Works
      “IWX Mx Engine Request”(XmlPort 70098270).OnPreXmlPort(Trigger) line 5 – MxAPS Advanced Finite Capacity Scheduling by Insight Works

       

      Mark GenglerMark Gengler
        Post count: 12

        Hi <span class=”bbp-author-name”>Astrid,</span>

        That error is usually the result of a blank value in one of “Time Unit of Meas. Code” fields in [Prod. Order Routing Line] which can occur if that “Time Unit of Meas. Code” is also missing in [Routing Line].  There are four fields to check and they are “Setup Time Unit of Meas. Code “, “Run Time Unit of Meas. Code”, “Wait Time Unit of Meas. Code “, and “Move Time Unit of Meas. Code”.  These fields are typically hidden, so you may have to use the Page Inspector (Ctrl-Alt-F1) to see which one(s) are blank and add them so you can change them.

        The Work Center Card page also has a “Unit of Measure Code” and both the Work Center Card and Machine Center Card pages have a “Queue Time Unit of Meas. Code”.

        If you ensure these fields have non-blank values that should resolve the error, although it is possible you have additional [Prod. Order Routing Line] records with issues.