# Using Special Characters in Quality Inspection Field Choices for Threshold Categories

Pass conditions are effectively Business Central filters.

When you are in a scenario where the pass condition contains special characters that have meaning to Business Central filters (such as <,>,|,&) then they need to be escaped.

This article will go through a common scenario of using “Less Than” Values as Quality Inspection Field Choices.  This scenario can occur in a lab result, when the lab result is reported as a category such as <10, <20, or <30.  Effectively, this is when the reported result is a threshold category rather than a precise numeric measurement.

This configuration can be useful when a laboratory reports results as predefined categories rather than an exact measurement.

Some common industry examples could be:

- **Microbiology counts**: `<10 CFU/g`, `<100 CFU/mL`, etc., when the organism count is below the method’s reporting or detection threshold.
- **Chemical contaminant testing**: `<10 ppb`, `<20 ppm`, etc., for pesticides, heavy metals, cleaning residues, or other analytes below a reporting limit.
- **Allergen testing**: results such as `<2.5 ppm`, `<5 ppm`, or `<10 ppm` where the lab reports that the allergen is below a quantifiable level.
- **Environmental/water testing**: `<0.10 µg/L`, `<1 mg/L`, etc., for contaminants that were not detected above the method’s detection limit. EPA laboratory guidance explicitly uses results such as `<0.10 µg/L` to represent non-detects.
- **Sanitation or hygiene testing**: predefined microbial or residue bands where the actual output is reported as “less than X” rather than an exact value.

## Configuration Example

In this example we’ll presume that the allowed choices should display as <10, <20, <30, <40 and <50, however it will only be considered a pass if either <10 or <20 or <30 is chosen.

- In Business Central, search for and open **Quality Inspector Fields**.
- Create a new Quality Inspector Field.
- Set **Field Type** to **Option**. Quality Inspector supports option/choice fields for a finite list of possible results.
- Enter the possible results in **Allowable Values**, separated by commas: `<10,<20,<30,<40,<50`
- Configure the **Pass** condition using single quotes around each literal value and `|` between acceptable results: `'<10'|'<20'|'<30'` **Important: Quotes are used because “<” has meaning to Business Central in the context of a filter string.**

### Related articles

- **[Quality Inspection Fields](/kb/quality-inspector/iwxqifields-page-al/)** – Configure fields, field types, allowable values, and default passing conditions.
- **[Configure Grades](/kb/quality-inspector/configure-grades/)** – Learn how Pass, Fail, and other grade conditions are evaluated.
- **[Create Quality Inspections for Receipts](/kb/quality-inspector/create-quality-inspections-for-receipts/)** – Example of configuring Quality Inspector fields and pass conditions for receiving inspections.

![Laboratory Result As a Category instead of empirical measurement.](/wp-content/uploads/kb-legacy/Screenshot-2026-08-19-120709-800x258.png)